Technician Work Sheet for Calculating Termiticide Application
MDAC’s Technician Work Sheet for Calculating Termiticide Application is Mississippi’s optional two-page form for the gallon math behind each termite treatment.
At a glance
- Records rule
- Rule 111.01
- Filled out by
- Calculator and applicator
- Due
- Every termiticide job
- Kept for
- Contract’s life + 2 years
Completed example
Download PDFWhat is the technician work sheet?
It’s the Bureau of Plant Industry’s two-page sheet for one termite job. You note the house, the termiticide, and the construction, then turn linear and square feet into gallons line by line, and the calculator and applicator both sign.
The sheet is optional. MDAC’s own words: “You are not required by Regulations to use the form.” The facts on it aren’t optional, though, so most offices use it anyway. MDAC’s PDF, Revised November 1, 2024, is the copy of record. Ours copies it item for item.
When do you fill it out?
For every termiticide application. Rule 111.01 wants the location, the brand and EPA number, the dilution, the total volume applied, and “sufficient information to determine termiticide volume.” A wood destroying insect company keeps it as long as any contract on the house runs, plus two years.
The math is the point. Rule 118.01(3) bars any job below the label’s concentration or volume, and the sheet is how an inspector checks it. Pretreats, perimeters, EP/LI, spots, and retreats all go on it.
How to fill it out
Measure before you mix. Walk the foundation and write the linear feet on the right line: 2a to 2d inside, 4a to 4d outside, by footing depth. A 204-foot perimeter on a 1-foot footing is 204 × 0.4 = 81.6 gallons on line 4a.
Use the right side of the table. Pretreats total on the left, existing houses on the right. On an existing house, voids (3) and 7B run at 2 gallons per 10 feet and the other linear lines at 4. Each formula says which lines to add.
Turn gallons into concentrate. Use your label’s mixing table. For 0.06% Termidor SC, that’s 78 fl oz per 100 gallons, so 87.2 gallons takes 68.0 fl oz. Double strength at half volume is only for soil that won’t take the full rate, and the reason goes in the remarks.
Write where and how in the remarks. For EP/LI, Rule 118.06(2) wants the areas and methods on the graph and the application records. Note any area the owner kept off the job, so it matches the exception on the treatment contract. The same job then goes on the monthly report.
Can you find the sheet when MDAC asks?
A sheet stays on file as long as the contract renews, plus two years. When an inspector asks, you need the right sheet for the right house, not a box of clipboards from 2026.
Noma specializes in the Technician Work Sheet for Calculating Termiticide Application (Rule 111.01). Each termite job lives in Noma with its schedule, invoice, and online payment, and your own contract can go out for e-signature. See how Noma runs termite jobs.
Frequentlyaskedquestions
Send this document in minutes, not an afternoon.
Other states
Termite treatment record templates- Arkansas
Termite Treatment and Retreatment Record
Record the termiticide, the amount, and the method for each job. - Colorado
Colorado post-construction termite treatment record (Part 6.04(b))
Record the termiticide, the amount, and the method for each job. - DelawareDocument # 65-01-06/01/09/02
Delaware Notice of Termiticide Application
Record the termiticide, the amount, and the method for each job. - Illinois
Illinois termite treatment record and diagram
Record the termiticide, the amount, and the method for each job. - Indiana
Indiana termite treatment record and graph
Record the termiticide, the amount, and the method for each job. - Kansas
Kansas termite treatment diagram and service worksheet
Record the termiticide, the amount, and the method for each job. - Kentucky
Kentucky termite treatment graph (302 KAR 26:090)
Record the termiticide, the amount, and the method for each job. - Louisiana
Termite Control Application and Bait Record
Record the termiticide, the amount, and the method for each job. - Maryland
Termite and Pre-Treat Application Record
Record the termiticide, the amount, and the method for each job. - New Jersey
New Jersey termiticide record and diagram (N.J.A.C. 7:30-6.8 and 7:30-10.4)
Record the termiticide, the amount, and the method for each job. - Ohio
Ohio termite treatment and bait station record
Record the termiticide, the amount, and the method for each job. - Oklahoma
Oklahoma Termite Treatment Application Record
Record the termiticide, the amount, and the method for each job. - South Carolina
Record of Termiticide Use
Record the termiticide, the amount, and the method for each job.

















