Waiver of Requirements of Minimum Specifications for Termite Control Work
In Louisiana, the waiver of minimum specifications is what the owner signs under LAC 7:XXV.141.H when part of a structure can’t be treated to the state’s termite specs, with a diagram, a description, and a reason for each area.
At a glance
- Required by
- LAC 7:XXV.141.H
- Filled out by
- The pest control operator
- Signed by
- Property owner or agent
- Due
- Before or during treatment
Completed example
Download PDFWhat is this waiver?
It’s the owner’s written OK to skip part of the state’s termite specs when an area can’t be treated the way §141 says. Think a patio poured against the slab, a finished floor over a bath trap, or a well too close to trench. You ask for it, and the owner or their agent signs.
Louisiana has no state form, but §141.H of the LAC 7:XXV (LDAF, March 2026) names three things it must include: an inspection diagram showing the structure and each waived area, a description of each area, and the reason for each. This form prints all three in the rule’s own words.
When is it signed?
Before or during treatment. That’s §141.H.1, and the owner gets a signed copy. Spot treatments and combination liquid spot and bait jobs need it before you start (§141.F.1 and J.6). The trench and treat basics in §141.B.1-3 “shall not be waived.”
Then there’s the monthly report. §141.F.1 still says a copy goes in with it, but LDAF’s 2026 AES-23-12 WDIE report says “Copies of waivers should not be submitted with monthly reports” and only asks Yes or No. Mark “Yes” on the monthly report and check with LDAF before you mail a copy.
How to fill it out
Tie it to the job. Fill in the owner, the structure’s address, your POB permit, the contract number, and the inspection date. Check whether it’s a first treatment, a retreatment, a spot job, or a combination spot and bait job.
Draw the structure and number each area. Sketch the outline, dash the parts you won’t treat, and write a number on each one. The same diagram goes on the termite contract, so keep the numbers the same.
Describe each area and give the reason. Be specific: “24 feet of brick patio against the rear slab” beats “patio.” Name the §141 spec you’re skipping, such as D.1.d for drilling an abutting slab, so an LDAF inspector can see what was left out.
Sign, then leave a copy. Check whether the owner signed before or during treatment, and both sides sign. Write down when the copy went to the owner and who gave it. Keep the original three years after the contract expires (§117.H).
Can the owner sign it before you get there?
On a spot job, no signature means no treatment. If the owner works days or lives out of town, the crew waits or the job gets pushed. Most of the waiver is known after the inspection, so it can go out early.
Noma specializes in the Waiver of Requirements of Minimum Specifications for Termite Control Work (LAC 7:XXV.141.H). Upload your waiver once as a reusable document and send it for e-signature, so the owner signs online before the crew arrives. See how Noma sends documents for signature.
Frequentlyaskedquestions
Send this document in minutes, not an afternoon.
Other states
Treatment waiver templates- Alabama
Official State of Alabama Waiver Form
Owners sign off on termite work that won’t be done. - Arizona
Refusal of Termite Re-treatment
Owners sign off on termite work that won’t be done. - Arkansas
Request for Exclusion of Certain Minimum Requirements for Structural Pest Work
Owners sign off on termite work that won’t be done. - Georgia
Official Waiver of the Georgia Minimum Treatment Standards for the Control of Subterranean Termites
Owners sign off on termite work that won’t be done. - Indiana
Indiana termite control customer disclosure
Owners sign off on termite work that won’t be done. - Mississippi
Written Request for Spot Treatment
Owners sign off on termite work that won’t be done. - New Jersey
New Jersey consumer information waiver (N.J.A.C. 7:30-9.12(b)3)
Owners sign off on termite work that won’t be done. - North CarolinaForm No. 5
North Carolina Official Waiver of Minimum Requirements
Owners sign off on termite work that won’t be done. - Oklahoma
Oklahoma Termite Treatment Exceptions and SPOT/PARTIAL Disclosure
Owners sign off on termite work that won’t be done. - South Carolina
Official Waiver of Minimum Treatment Standards
Owners sign off on termite work that won’t be done. - Tennessee
Tennessee less than complete termite treatment acceptance
Owners sign off on termite work that won’t be done.