Site-Specific Structural Fumigation Log

Washington’s site-specific structural fumigation log is the Vikane label’s record of a tent job, plus the three fumigation items the state’s record rule adds, kept seven years.

At a glance

Required by
Vikane label, WAC 16-228-1320
Filled out by
Certified applicator in charge
Due
(B) items before the start
Keep for
7 years

Completed example

Download PDF
What is this log?
It’s the record of one structural fumigation, from the dose math to the final clearance test. The fumigant’s label sets most of it, and the certified applicator in charge makes sure it’s complete.
Washington adds three items to the label’s list: pounds of gas per 1,000 cubic feet, the temperature, and the exposure time. The red sign posted on the same job is on the fumigation warning sign page.
When do you fill it out?
Start it before the tarps go up. The Vikane label marks five items “(B)”: the company, site address, structure type, target pests, and volume. The rest goes in as the job runs. EPA’s site log page lists the same items for states with no log rule, like Washington.
Under WAC 16-228-1320, as amended January 1, 2026, the record is due the same day the gas goes in and stays on file seven years. The same rule asks for the three fumigation items.
How to fill it out
Do the (B) items first. Fill in section 1 and the volume on the walk-through. For anobiid (powderpost) beetles, the label’s dosage factor is 10X, since the eggs take ten times the drywood termite dose.
Fill the (WA) boxes. Divide the pounds released by the volume in thousands of cubic feet. Write the temperature at the coolest spot the pests are, often the crawl space soil, and the hours from release to the first opening of the seal.
Check your crew. Under WAC 16-228-1548, anyone without a license who handles a restricted use fumigant must be 18 or older and qualified. The license itself has to be space (nonsoil) fumigation, per WAC 16-228-1545.
Wait, then clear each room. Homes stay shut at least 12 hours from the first opening. A dose over 16 oz/MCF uses procedure 2, which stretches that to 14 to 24 hours. Test each room with a device on EPA’s list until it reads 1 ppm or less.
Where does it fit in the job?
A beetle job can keep the tarp on for two days, and the log passes through a lot of hands. When it lives on a clipboard in the truck, the (WA) boxes and the clearance readings are the first things to go missing.
Noma specializes in the Site-Specific Structural Fumigation Log (Vikane label, WAC 16-228-1320). Upload your fumigation contract once, send it for e-signature on each job, and schedule and invoice the fumigation in the same place. See how Noma runs fumigation jobs.
Frequentlyaskedquestions

Send this document in minutes, not an afternoon.

Other states