Site-Specific Structural Fumigation Log
South Carolina’s site-specific structural fumigation log is the record the Vikane label says to keep for every tent job, plus the state’s own lines for the 7B applicator, the fire notice, and beetle frass.
At a glance
- Required by
- Fumigant label (27-1084)
- Filled out by
- Certified applicator in charge
- Due
- (B) items before the start
- Kept for
- 5 years on wood pest jobs
Completed example
Download PDFWhat is this log?
It’s the record of one structural fumigation, from the dose math to the final clearance test. South Carolina doesn’t print one. The Vikane label lists what every log has to hold, and the state’s rules make the label binding.
This one adds a box for South Carolina’s own items: the 7B applicator on site, the fire officials’ notice, the watchperson, and beetle frass. The notices that go out before the same job are on the notice of fumigation page.
When do you fill it out?
Start it before the gas goes in. Under Reg. 27-1084(A)(1), using a pesticide against its label is a violation. The Vikane label marks five items “(B)”: the company, site address, structure type, target pests, and volume. Those go down before the fumigation starts.
The rest goes in as the job runs. EPA’s site log page adds the number of fans and the nearest hospital. Note when the written notice reached the fire officials, since IFC 2603.3 wants it there 48 hours before the building is closed.
How to fill it out
Do the (B) items first. Fill in section 1 and the volume on the walk-through, before the tarps go up. On a beetle job, use the label’s 10X dosage factor, and note the fresh frass that showed the infestation was active.
Log the release. Write who put in the chloropicrin and gas, their license number, and who helped. Then the cylinder numbers, the pounds, and the time, plus the Category 7B applicator who stayed on site the whole time.
Clean off the frass. On beetle jobs, Reg. 27-1085(I)(4)(b) has you clear frass from at least two easy-to-reach spots during the fumigation. Write down where, because streaming frass there next season means the beetles survived.
Clear it room by room. A dose over 16 oz/MCF calls for aeration procedure 2, which waits 14 to 24 hours from the first opening. Then test each room’s breathing zone with a device on EPA’s clearance device list, and okay re-entry only at 1 ppm or less.
Where does it fit in the job?
A beetle job can keep a house under tarps for two days and closed for a third, and the log passes through a lot of hands. When it lives on a clipboard in the truck, the clearance readings go missing first.
Noma specializes in the Site-Specific Structural Fumigation Log (Vikane label, Reg. 27-1084(A)(1)). Upload your fumigation contract once, send it for e-signature on each job, and schedule and invoice the fumigation in the same place. See how Noma runs fumigation jobs.
Frequentlyaskedquestions
Send this document in minutes, not an afternoon.
Other states
- Arizona
Site-Specific Structural Fumigation Log
Record the gas, the dose, and the clearance for each fumigation. - Florida
Fumigation Log
Record the gas, the dose, and the clearance for each fumigation. - Texas
Structural Fumigation Report and Log
Record the gas, the dose, and the clearance for each fumigation. - Washington
Site-Specific Structural Fumigation Log
Record the gas, the dose, and the clearance for each fumigation.