Structural Fumigation Record
Nevada’s structural fumigation record is the company’s own log of one tent job: the NDA record items, the Vikane label’s log, the on-site checks, and the clearance, kept for 2 years.
At a glance
- Required by
- NAC 555.410 and 555.700
- Filled out by
- Certified applicator
- When
- During each fumigation
- Kept
- 2 years
Completed example
Download PDFWhat is this record?
It’s the company’s own log of one tent job, from the dose math to the last clearance reading. The certified applicator in charge fills it out and the office keeps it. Nobody files it with NDA, but a missing record can draw a fine under NAC 555.530.
Nevada’s version pulls from four places. NDA’s record rules, NDA’s on-site rule, the Vikane label’s fumigation log, and the fire code all ask for something. The written warnings sent before the job are on the fumigation notice page.
When do you fill it out?
Start it before the tarp goes on. The label marks the items due before the gas goes in with (B), like the site address and the volume. Under NAC 555.410 and NAC 555.700, the weather and times go in at the start and the finish.
Keep it 2 years. The on-site checks come from NAC 555.510 and the 2018 fire code. Local fire agencies can add their own rules, so check with yours.
How to fill it out
Do the (B) items at the office. The company, site, structure, pests, and volume come straight from the Vikane label’s log list. Add the customer, the site treated, and the purpose for Nevada.
Write the weather twice. Nevada wants the temperature and the wind speed and direction at the start and at the finish. The label wants the temperature at the coolest spot where the pests are, so write that in the dosing row too.
Check off who and what is on site. Page two lists NAC 555.510’s checks: the certified applicator, the second person, the label, any plan, and any antidote. Log your contacts with the crew, every hour at night and every 2 hours in daylight.
Clear it room by room. Write each room’s reading from your clearance device. Every one has to be 1 ppm or less before re-entry, and a certified applicator signs off before the placards come down.
Where does the paperwork live?
A tent job’s papers end up in the truck, the office, and someone’s inbox. When someone asks about last year’s job, you want the contract, the notices, and the log for that address in one place.
Noma specializes in the Structural Fumigation Record (NAC 555.410). Each fumigation is a job with its schedule, invoice, and online payment, and your own contract goes out for e-signature when it’s booked. See how Noma runs fumigation jobs.
Frequentlyaskedquestions
Send this document in minutes, not an afternoon.
Other states
Fumigation log templates- Alabama
Alabama Structural Fumigation Log
Record the gas, the dose, and the clearance for each fumigation. - Arizona
Site-Specific Structural Fumigation Log
Record the gas, the dose, and the clearance for each fumigation. - Florida
Fumigation Log
Record the gas, the dose, and the clearance for each fumigation. - Hawaii
Fumigation Job Log
Record the gas, the dose, and the clearance for each fumigation. - Louisiana
Fumigation Record and Gas Reading Log
Record the gas, the dose, and the clearance for each fumigation. - Maryland
Structural Fumigation Log
Record the gas, the dose, and the clearance for each fumigation. - South Carolina
Site-Specific Structural Fumigation Log
Record the gas, the dose, and the clearance for each fumigation. - Texas
Structural Fumigation Report and Log
Record the gas, the dose, and the clearance for each fumigation. - Washington
Site-Specific Structural Fumigation Log
Record the gas, the dose, and the clearance for each fumigation.