Fumigation Warning Sign

Florida’s fumigation warning sign is the red DANGER/PELIGRO sign Rule 5E-14.112 says to post at every door and on every side of the tarp before the gas goes in.

At a glance

Required by
Rule 5E-14.112, F.A.C.
Posted on
Every door and every tarp side
Printed
Red on white, 11 by 17
Comes down
After clearance (5E-14.113)

Completed example

Download PDF
What is this sign?
It’s the red DANGER/PELIGRO sign that goes on a house before any gas goes in. Florida doesn’t leave the wording to the label. Its rule spells out every line, from the skulls down to the night phone number.
Florida rewrote the sign on May 18, 2026, so older Florida signs that say “Fumigating with” and “All Persons are Warned to Keep Away” no longer match. The rule also wants every other letter at least ½ inch tall, which won’t fit on Letter paper, so this one prints on 11 by 17. The record you keep for the same job is on the fumigation log page.
When does it go up?
Before the gas goes in. Under Rule 5E-14.112, a tent job gets at least one sign at every door and entrance and at least one on every side of the tarp. Skip them and FDACS can stop the job on the spot under s. 482.051(6), F.S..
Tarp signs stay up until aeration starts. Door signs stay up until aeration is done and the operator declares the house safe under Rule 5E-14.113. That’s when the notice of clearance goes up in their place.
How to fill it out
Print it in red, full size. Print the PDF on 11 by 17 paper at 100%. The rule wants red ink that won’t run in water, so use a color laser printer, then mount the sheet on corrugated plastic or laminate it.
Write the brand name big. It has to be at least 5/8 inch tall, so print the brand, like VIKANE, in capitals with a waterproof marker. Write every other blank at least ½ inch tall too.
Fill in the people and phones. Add the company, its business address, the certified operator in charge, and who put the gas in. The day and night numbers have to reach a trained person right away. A staffed 24-hour answering service works; voice mail doesn’t.
Post, release, then add the time. Put the signs up and lock every outside door with a secondary lock before the release. Write the date and time the gas went in on each sign as soon as it’s in.
Where does it fit in the job?
A Florida tent job runs on paper: the contract, the Fact Sheet, the 24-hour notice to FDACS, the log, and a stack of signs. Forget the signs and the release waits while someone drives back to the shop.
Noma specializes in the Fumigation Warning Sign (Rule 5E-14.112, F.A.C.). Upload your fumigation contract once, send it for e-signature on each job, and schedule and invoice the fumigation in the same place. See how Noma runs fumigation jobs.